1. Large, medium and small electric vehicle charging stations;
2. High-speed service areas, stations, docks and other transportation hub areas;
3. Public places such as urban residential areas, shopping plazas and electric business places.
| Category | Name | Parameter |
|---|---|---|
| Model | BEG75050-40KW | |
| Environmental Conditions | Operation temperature | -40°C ~ +75°C (derating above 55°C) |
| Storage temperature | -40°C ~ +70°C | |
| Relative humidity | ≤95%RH, without condensation | |
| Cooling mode | Forced air cooling | |
| Altitude | 2,000 m (derating above 2,000 m) | |
| Atmospheric pressure | 79 kPa ~ 106 kPa | |
| AC Input | Voltage range | 260 Vac ~ 530 Vac |
| Rated voltage | 400 Vac | |
| Maximum current | 64A | |
| Grid frequency | 45 Hz~ 65 Hz | |
| DC Output | Voltage range | 50 Vdc ~ 750Vdc |
| Current range | 0 ~ 66.6A (high voltage) / 0~100A (low voltage) | |
| Steady voltage precision | <±0.5% | |
| Power Factor | ≥0.99 @100% Load | |
| Efficiency | ≥95.2% @750V | |